48re Transmission Cooler Line Diagram. 48re Transmission Coolers. A failure of this type usually results in a rebuild to the tune of at least $1200 or more. Well, if you have debris in your trans fluid from normal wear and tear, a common place for it to collect is in the check valve. What size are transmission cooler lines. Well, here's a little write up to remove the tranny check valve in the return line to increase flow to the trans and hopefully remove a common failure point in the Dodge 46re transmission. Here's a pic of the check valve side brass fittings (you can see these assembled in the quick disconnect tool pic posted earlier.
- What size are transmission cooler lines
- How to change transmission cooler lines
- Changing transmission cooler lines
- Transmission cooler hose lines
- What is a 1/8 bend in plumbing lines
- What is a 1/8 bend in plumbing supply
- What is a 1/8 bend in plumbing pipe
- What is a 1/8 bend in plumbing drain
- What is a 1/8 bend in plumbing parts
- What is a 1/8 bend in plumbing water
What Size Are Transmission Cooler Lines
1 or 2 quarts ATF +4 trans fluid. 1 - quick disconnect fitting (NAPA part #730-5027). Trans oil catch pan. Search for: Main Menu. Changing transmission cooler lines. Here's the replacement hose completely assembled: 1 ft of trans tubing will probably be a little too long for the setup so you can use wire cutters to cut the trans tubing to size. Here's a pic of the 3 pieces that go onto the radiator side of the hose (I believe that coupler was 21mm on the outside): And here's a close up pic of the NAPA replacement Quick Connect fitting. Notice it says DODGE/JEEP at the top: The parts guy said he could order a quick connect with a female end that might attached directly to the 3/8" nozzle without the reducer, but I wasn't going to wait a day for a "maybe fits" part.
NAPA part #05706B106). I just bought this one and used a reducer they had in stock. Let the truck heat up to operating temp and check the trans fluid level on a level road or parking lot. Sorry for the few out of focus pictures, my camera doesn't like to focus without a flash which was necessary for some pics.
How To Change Transmission Cooler Lines
4l80e Transmission Parts Diagram. 3/4" open end wrench. The brass fitting might have corroded a bit so a shot of penetrating oil will help break it loose. The tip on the nozzle serves as a catch so that the band clamp (when tightened down) can't slide backward. Parts like Transmission Oil Cooler & Lines are shipped directly from authorized Mopar dealers and backed by the manufacturer's warranty. Transmission cooler hose lines. Make sure you place a catch pan under the fitting before you disconnect it as trans fluid will start to drip from the radiator.
You simply slide the disconnect tool over the trans cooler line on the radiator side with the flanges pointing toward the check valve and press the tool into the fitting and then pull the fitting and hose away from the radiator. I suggest you leave it on the tool and just shove the disconnect tool straight down onto the radiator pipe. Crescent wrench for various metric fittings somewhere between 17mm and 21mm. Harbor Freight has them here. The 7/8" wrench should fit on the check valve and the 3/4" should go on the silver connector on the the trans return line. When you remove the check valve tube trans fluid will drip from the trans line, so position your drip pan under there as well. Guides & Information. The nozzle end will go into the hose and then you'll use the band clamps to secure it. Next we need to construct a new replacement hose with fittings. A flat head screwdriver.
Changing Transmission Cooler Lines
It's a good idea to let the truck idle in neutral for about 10 seconds before taking off after the truck has sit for an extended length of time. The large brass fitting contains the the check valve in question. Deleting the Transmission Check Valve. Enjoy your new found peace of mind. A razor blade won't work because the trans line is reinforced with steel mesh to keep it from expanding. 1 - 3/8" to 1/4" reducer coupling (NAPA part #3300X6X4). You'll notice the flow direction is marked on the old check valve itself. The next pic is the connection on the radiator side: It is typically held on with a quick connect fitting and you will need to first pop off the safety connection with a flat head screw driver.
Here's a pic of the NAPA trans line (I bought their last 3 feet, so they gave me the box): That hose was rated for 400PSI! It's tiny and once you see it, you'll understand why it's a restriction to the system and how debris can accumulate there, especially is the tranny doesn't see a regular servicing. The first pic is of the check valve as it sits in the stock truck in the transmission return line from the radiator. Here's a pic of it installed: Engage the emergency brake and start up the truck and put it in Neutral. When this happens, the fluid flow can eventually stop and with no way to cool the internals of the transmission, it will overheat and die. First we need 1 ft of hose. Offers the wholesale prices for genuine 2001 Dodge Ram 1500 Regular Cab parts. Insert radiator side coupling and tighten down the hose clamp over the fitting's nozzle end.
Transmission Cooler Hose Lines
Make sure it is 3/8" ID trans cooler line hose and nothing else! You must be logged in to rate content! This will allow the trans fluid pump to refill the Torque Converter so you don't bog and stall as you try to take off. Tighten up the flare end onto the coupler in the truck and push the quick connect side onto the radiator. Then remove the tool.
The reason that you can't use just the nozzle piece is because the coupler in the truck on the check valve side is a flare thread which is different from pipe thread. The new fittings will make the whole unit a little longer than the old one, so don't judge rubber tubing to rubber tubing when you cut. This setup is also nice if you ever want to add an external cooler or filter to the trans return line. 1 - 3/8" to 3/8" male-to-male coupler (will research P/N). 1 - 3/8" pipe thread to flare thread converter (will research P/N). After you remove the check valve line, turn it quick connect side down and let the trans fluid drip out.
Recheck all of the connections. 2 - hose clamps (NAPA part #5051212). RTV should not be needed if you get the fittings tight, but won't hurt if you want to use it, just use sparingly on the threads and make sure it is highly oil resistant and can take at least 250 degress. 1 ft of 3/8" ID trans cooler line (NAPA part #H1937). 48re Transmission Guide & Information. Parts fit for the following vehicle options. Add more ATF +4 as needed. The nozzle will slide right into the hose and the band clamp will fit perfectly over the flat portion of the nozzle.
Compliments of aim4squirrels @. You can now remove the drip pan. The replacement is a return line with no check valve that replaces the current line without hacking up any of the truck's trans lines or fittings. 3/8" quick disconnect tool. Just stuff the replacement check valve fitting unit in one end of the hose, clamp it down with a hose clamp and hold it up to the old check valve line before you cut. So why on earth would you want to remove this?
Please contact your local Coburn's location to find out if the item can be ordered from the manufacturer and the estimated time it would take to be shipped. What is the angle of a 1 6 bend?
What Is A 1/8 Bend In Plumbing Lines
Temperature Range: 32 to 140 Deg F. A 4 by 3 reducing long sweep 1/4 bend has a 4-inch SPIGOT on one end, reducing 90 degrees to a 3 1/4-inch HUB on the other end. Those products can only be priced by contacting your local Coburn's location. Residential Products Resource Library. Designed to connect two pipes at a 22.
What Is A 1/8 Bend In Plumbing Supply
A 1/8 bend is used to change the direction of a cast-iron soil pipeline 45 degrees. Elbows typically have a radius of curvature that ranges from one to twice the diameter of the pipe they are connecting. Black Cast Iron pipe/fittings for drain, waste and vent (DWV) applications Premier piping system that withstands extreme temperatures and conditions Excellent sound-deadening qualities Manufactured from 100% recycled content; not intended for pressure use. Size of 1-1/2″ DWV PVC pipe. Setup and Transportation. Exalted activity will have neither good Plumbing nor good philosophy: neither its pipes nor its theories will hold water. " Sealants and Adhesives. What is a 1/8 bend in plumbing supply. There are three responses. 3 Reviews For The Product. Both cast-iron soil pipe and fittings are brittle, so exercise care to avoid dropping them on a hard surface. Foundation Covers Warranty. Plus you have the 45's you can use if you endd up needing them and seperate it is easier to store on a truck since they are not put together. On certain products there is no guarantee that the manufacturer shown is the actual manufacturer of the product.
What Is A 1/8 Bend In Plumbing Pipe
As NH Master said, they are not readily available in PVC in this area. Over 687, 000 strictly plumbing related posts. There are no combys sold in NH? An elbow is a technical phrase that may be classed as 90-degree or 45-degree, short- or long-radius, respectively. Our site is completely free, without ads or pop-ups. Of the half dozen local supply houses around here, none carry them. What is a 1/8 bend in plumbing pipe. Manufactured Housing Team. Bending is a general phrase that refers to any offset or change in direction in pipe systems. Sweep plumbing bends are huge radius elbow pipe fittings that are often utilised in drain and vent line applications. DWV, SEWER, STORM DRAINAGE, SANITARY DRAIN APPLICATION. Tools and Fasteners.
What Is A 1/8 Bend In Plumbing Drain
1/8 SHORT TURN TYPE; CAST IRON MATERIAL; 3 INCH SIZE A; 3 INCH SIZE B; 3 INCH MJ X 3 INCH MJ END CONNECTION; 45 DEG ANGLE; 3 INCH BEND RADIUS; WEIGHT 2. Please review our Terms of use. Click For Details Helpful Links Shop Our Sale Flyer About Us Store Locator My Account Wholesale Farm Sales Municipal Division Dealer Login Questions? Catalogs and Brochures. What is a 1/8 bend in plumbing lines. Of a hub and spigot). SANITARY TEE RED DWV. Repair your leaking Plumbing fixtures ASAP [. Please select the file format you want to download.
What Is A 1/8 Bend In Plumbing Parts
Note that for all CISP fittings, the spigot end is always listed first. 3) Traps that are not permitted. Even Home Depot and Lowes have combos. A wye is a fitting that has three apertures that is used to link (or produce) branch lines.
What Is A 1/8 Bend In Plumbing Water
Plumbing PVC Elbow 3" x 3", Hub, 1/8 Bend, 45°, 20/Carton. We are made possible by: Author: sum (FL). MANUFACTURED PRODUCTS. Be the first to write a review ». You can use a street 45 and make a comby or you can just use the wye or if you missed on your pipe measurement you can use a regular 45 and install a piece of pipe to get you too the right spot. HVAC Service Documents. PLUMBERS "Protecting The Health Of The Nation". This 1/6 bend low heel inlet elbow, also known as a "ell, " connects two pipes, both of which have hub connections, to change the direction of flow between pipes by 60 degrees. So, with that in mind, how many degrees does a 1/16 Bend equal?
GRAY CAST IRON MATERIAL. In order to give the unit the form of the letter "P, " two 90-degree joints are combined with a horizontal overflow pipe, giving the whole thing its name. So we use the Wye and 1/8 bend. Just curious about this term "Combination Wye & 1/8 Bend Hub" I know what a Wye is, but why is it a "Combination" and what does the "1/8 bend" mean? Hub ends are used to join male unthreaded pipes or fittings together. Besides it takes up way too much space. In all circumstances, venting is required for all traps. Now you've done it... That will be his next question... My realtor told me that she helped out in her father's hardware store one summer and when a customer asked for a "3/8 nipple" she slapped him. Coverage Transparency.
Steps, Decks, and Rails. Minimum Temperature: 32. British Virgin Islands. Coburn Supply has made every effort to display accurate information. ANSI Specifications: ANSI B16. According to the description above, the sweep 90 is utilised for DW pipes when there is a substantial amount of waste water involved, and particularly when there are particles in the waste. Getting back to the "S" traps – The reason "S" traps aren't permitted is because they have the potential of sucking, or "syphoning, " water out of the trap while the water is being flushed down the toilet. Perrenia Resource Library. This download is available in more than one file format. Page Loading... BIBBY STE-CROIX. The Carrington Collection Resource Library. Interior Doors and Trim. Some of the cast-iron soil pipe fittings you may use in your work are described below.